Every dormer loft conversion needs building regulations approval, whether or not it needs planning permission. Building control inspects the work in stages and issues a completion certificate at the end.
What does building control check?
Structure (Part A): new floor joists, beams and the dormer frame, to a structural engineer's design. Fire safety (Part B). Stairs and guarding (Part K). Insulation (Part L). Ventilation (Part F). Sound between rooms (Part E), drainage (Part H) and electrical safety (Part P).
What are the fire safety requirements?
When a two-storey house gains a third storey, the stairway must become a protected escape route to the front door. In practice that means fire-resisting doors to the rooms that open onto the stairs, 30 minutes' fire resistance to the new floor, and mains-powered interlinked smoke alarms on every storey. An escape window alone is not accepted at that height.
What are the rules for the new stairs?
Headroom should be 2.0 metres, although for loft conversions 1.9 metres at the centre of the stair and 1.8 metres at the side is accepted. The pitch must not exceed 42 degrees and the stairs need a handrail and guarding. A fixed ladder or a space-saver stair is only acceptable in limited cases.
How well must a dormer be insulated?
New walls and roofs in an existing home have target U-values in Approved Document L: 0.15 W/m²K for roofs and 0.18 W/m²K for walls, including dormer cheeks. Windows must achieve 1.4 W/m²K or a band B energy rating.
Who provides building control?
Either your local authority or a registered building control approver. Either can check plans before work starts, which we recommend, then inspect at set stages. Keep the completion certificate with your deeds.
Does it differ in Wales?
Wales has its own Approved Documents, and some requirements differ in detail. The process is the same: approval, inspections and a completion certificate.